Visit #14
Uniwater
Salt Lake, Kolkata
2026-05-18
Site
3-BHK apartment
Salt Lake CK Block
Kolkata, 700091
System
HomeSoft 2K LPH Automatic
4-stage train · FRP vessels
Installed 2025-03-14

Parameters logged

ParameterBeforeAfterTargetStatus
TDS (ppm)412388< 500OK
Hardness (ppm CaCO₃)3822< 60OK
Iron (ppm)0.09< 0.03< 0.10OK
pH7.47.36.5–8.5OK
Free residual chlorine (ppm)0.4< 0.05< 0.1 post-treatmentOK
Inlet pressure (bar)2.12.11.8–3.5OK
Outlet pressure (bar)1.81.9> 1.5OK

Work performed

  • Inlet sediment pre-filter inspected, backwashed. No replacement needed.
  • Iron filter regen cycle verified. Media bed depth measured at 320 mm (target 300–350). No top-up required this visit.
  • Activated carbon filter — chlorine breakthrough test passed (post-stage residual < 0.05 ppm). Carbon life remaining ~9 months.
  • Softener resin — hardness leakage test passed. Salt tank checked, refilled 22 kg (next refill ~ Aug 2026).
  • Multiport valve seal inspected, lubricated. No leak.
  • Drain line clear. Bypass valve operates correctly.

Flags raised

None this visit. Carbon filter life is projected to fall below 6 months by the next visit — we’ll plan the replacement on visit #15 in line with the AMC schedule. No customer action required.

Next visit

Visit #15 — scheduled 2026-06-17

Same engineer. Same time slot. We’ll WhatsApp you the day before to confirm.

Engineer
Suman Saha
Senior service engineer · Uniwater Kolkata
Customer signature